Finden Sie schnell xlr kabel für Ihr Unternehmen: 369 Ergebnisse

RE-2Y(St)H-TIMF&RE-2X(St)H-TIMF

RE-2Y(St)H-TIMF&RE-2X(St)H-TIMF

HALOGEN-FREE INSTRUMENTATION CABLES, Acc. to BS 5308 PART 1 TYPE 1RE-2Y(St)H-TIMF,MULTI-TRIPLE, PE INSULATED, INDIVIDUAL & COLLECTİVE SCREENED, LSZH SHEATHEDRE-2X(St)H-PIMF,MULTI-TRIPLE, XLPE INSULATED, INDIVIDUAL & COLLECTİVE SCREENED, LSZH SHEATHED These cables are used for transmission of analoge and digital signals in instrument and control systems at chemistry and petrochemistry industry plants, power plants, natural gas and petroluem plants, etc... . Instrumentation cables are not allowed for direct connection to a low impedance sources, e.g. public mains electricity supply. In case of fire, these cables inhibit the propagation of the flames whereby the development of smoke is extremely low. No corrosive gases are emitted in the event of fire. With blue sheath it is suitable for intrinsically safe systems. These cables are not recommended for direct burial. They are for indoor and oudoor installation, in dry and wet locations; on racks, trays, in conduits. Conductor: Plain annealed copper wire, BS 6360, 0,50 mm2 and 1,0 mm2 solid, 0,50 mm2 and, 0,75 mm2 flexible or 1,5 mm2 stranded Insulation (2Y): PE compound, BS 6234 Type03 (RE-2Y….) Insulation (2X): XLPE compound, GP8, BS 7655 (RE-2X….) Core identification: Black / White / Red; with numbered tape under, separator tape of the pair screen, *Upon request ; Black / White / Red cores numbered 1-1-1, 2-2-2,… Triple: Three conductors twisted to a triple TIMF Construction: Polyester tape above the triple, AL-PES tape, over tinned copper drain wire, 0,50 mm2 Lay-up: TIMF laid up in layers of optimum pitch Separator: Polyester tape Screen: AL-PES tape over tinned copper drain wire 0,50 mm2 Outer sheath: LSZH compound, LST1, BS 7655, LSZH : Low Smoke Zero Halogen Sheath colour: RAL 9005, Black or RAL 5015, Blue Standard: Designed acc. to BS 5308 Part 1 Type 1 Insulation thickness: 0,50mm2 : 0,50mm, 1,0mm2 : 0,60mm, 0,50mm2 : 0,60mm, 0,75mm2 : 0,60mm, 1,50mm2 : 0,60mm Conductor resistance: 0,50mm2 : 36,8 Ω/km, 1,0mm2 : 18,4 Ω/km, 0,50mm2 : 39,7 Ω/km, 0,75mm2 : 26,5 Ω/km, 1,5mm2 : 12,3 Ω/km Insulation resistance: Min. 5000 MΩ.km Mutual Capacitance: 0,50 mm2 : max. 115 pF/m, 0,75 mm2 : max. 115 pF/m, 1,0 mm2 : max. 115 pF/m, 1,5 mm2 : max. 120 pF/m Capacitance unbalance: (1 kHz) : max. 250 pF/250 m L / R (ratio) (max.): 0,50mm2 : 25 µH/Ω, 0,75mm2 : 25 µH/Ω, 1,0mm2 : 25 µH/Ω1,5mm2 : 40 µH/Ω Rated voltage: 300/500V Test voltage: Urms core-core : 1000 V, Urms core-screen : 1000 V Temperature range (2Y): operation : - 40 oC ~ + 70 oC, ınstallation : - 5 oC ~ + 50 oC Temperature range (2X): operation : - 40 oC ~ + 90 oC, ınstallation : - 5 oC ~ + 50 oC Min. bending radius: 6 x D Flame retardance test: IEC 60332-1 & BS EN 60332-1, IEC 60332-3 & BS EN 50266-2-4 Smoke density test: IEC 61034-2 & BS EN 61034-2 Halogen-free properties test: IEC60754-1/2 & BS EN 50267-2 Conductor class, BS 6360: 0,50mm2 : Class 1, 1,0mm2 : Class 1, 0,50mm2 : Class 5, 0,75mm2 : Class 5, 1,5mm2 : Class 2
RE-2Y(St)HSWAH-PIMF&RE-2X(St)HSWAH-PIMF

RE-2Y(St)HSWAH-PIMF&RE-2X(St)HSWAH-PIMF

HALOGEN-FREE INSTRUMENTATION CABLES, Acc. to BS 5308 PART 1 TYPE 2RE-2Y(St)HSWAH-PIMF,SINGLE & MULTI-PAIR, PE INSULATED, INDIVIDUAL & COLLECTİVE SCREENED, ARMOUR, LSZH SHEATHEDRE-2X(St)HSWAH-PIMF,SINGLE & MULTI-PAIR, XLPE INSULATED, INDIVIDUAL & COLLECTİVE SCREENED,ARMOUR, LSZH SHEATHED These cables are used for transmission of analoge and digital signals in instrument and control systems at chemistry and petrochemistry industry plants, power plants, natural gas and petroluem plants, etc... . Instrumentation cables are not allowed for direct connection to a low impedance sources, e.g. public mains electricity supply. In case of fire, these cables inhibit the propagation of the flames whereby the development of smoke is extremely low. No corrosive gases are emitted in the event of fire. With blue sheath it is suitable for intrinsically safe systems. The armour above the inner sheath protects the cable from mechanical shocks. These cables are recommended for direct burial. They are for indoor and oudoor installation, in dry and wet locations; on racks, trays, in conduits. Conductor: Plain annealed copper wire, BS 6360, 0,50 mm2 and 1,0 mm2 solid, 0,50 mm2 and, 0,75 mm2 flexible or 1,5 mm2 stranded Insulation (2Y): PE compound, BS 6234 Type03 (RE-2Y….) Insulation (2X): XLPE compound, GP8, BS 7655 (RE-2X….) Core identification: Black / blue ; with numbered tape under, separator tape of the pair screen, *Upon request ; Black / White cores numbered 1-1, 2-2,… Pair: Two conductors twisted to a pair PIMF Construction: Polyester tape above the pair, AL-PES tape, over tinned copper drain wire, 0,50 mm2 Lay-up: PIMF laid up in layers of optimum pitch Separator: Polyester tape Screen: AL-PES tape over tinned copper drain wire 0,50 mm2 Bedding: LSZH compound, Blackk Armour: Galvenized round steel wire, BS EN 10257-1 Outer sheath: LSZH compound, LST1, BS 7655 Sheath colour: RAL 9005, Black or RAL 5015, Blue Standard: Designed acc. to BS 5308 Part 1 Type 1 Insulation thickness: 0,50mm2 : 0,50mm, 1,0mm2 : 0,60mm, 0,50mm2 : 0,60mm, 0,75mm2 : 0,60mm, 1,50mm2 : 0,60mm Conductor class, BS 6360: 0,50mm2 : Class 1, 1,0mm2 : Class 1, 0,50mm2 : Class 5, 0,75mm2 : Class 5, 1,5mm2 : Class 2 Conductor resistance: 0,50mm2 : 36,8 Ω/km, 1,0mm2 : 18,4 Ω/km, 0,50mm2 : 39,7 Ω/km, 0,75mm2 : 26,5 Ω/km, 1,5mm2 : 12,3 Ω/km Insulation resistance: Min. 5000 MΩ.km Mutual Capacitance: 0,50 mm2 : max. 115 pF/m, 0,75 mm2 : max. 115 pF/m, 1,0 mm2 : max. 115 pF/m, 1,5 mm2 : max. 120 pF/m Capacitance unbalance: (1 kHz) : max. 250 pF/250 m L / R (ratio) (max.): 0,50mm2 : 25 µH/Ω, 0,75mm2 : 25 µH/Ω, 1,0mm2 : 25 µH/Ω1,5mm2 : 40 µH/Ω Rated voltage: 300/500V Test voltage: Urms core-core : 1000 V, Urms core-screen : 1000 V Temperature range (2Y): operation : - 40 oC ~ + 70 oC, ınstallation : - 5 oC ~ + 50 oC Temperature range (2X): operation : - 40 oC ~ + 90 oC, ınstallation : - 5 oC ~ + 50 oC Min. bending radius: 8 x D Flame retardance test: IEC 60332-1 & BS EN 60332-1, IEC 60332-3 & BS EN 50266-2-4 Smoke density test: IEC 61034-2 & BS EN 61034-2 Halogen-free properties test: IEC60754-1/2 & BS EN 50267-2
Crimpwerkzeug mechanischer Quertransort

Crimpwerkzeug mechanischer Quertransort

Schnellwechselcrimpwerkzeuge, Crimpwerkzeuge, mit mechanischen oder pneumatischem Quertransport Unsere bereits vielfach im Einsatz bewährten Crimpwerkzeuge sind zur Herstellung von Verbindungen zwischen Leitungen und Kontakten in den unterschiedlichsten Anwendungsbereichen mit höchsten Qualitätsansprüchen konzipiert. Mit den Werkzeugen mit Schnellwechselsystem können nahezu fast alle auf dem Markt befindlichen quer gegurteten Crimpkontakte der unterschiedlichsten Hersteller verarbeitet werden. Alle Formen der Anbindung wie vorn, mittig, hinten oder doppelt gegurtet können verarbeitet werden. Nach Kundenangabe wird die Schneideeinheit so ausgelegt, dass der Kontaktstreifen entweder geschnitten oder aus dem Crimpwerkzeug geführt wird. Die Kontaktzuführung kann standardmäßig von links, aber auch als Sonderversion von rechts erfolgen. Unsere Schnellwechsel-Crimpwerkzeuge sind kompatibel und in nahezu allen handelsüblichen mit Schnellwechsel-System (auch AMP-kompatibel genannt) ausgestatteten Tisch-Crimppressen, Stripper-Crimper und Crimpvollautomaten einsetzbar. Die Fertigung aller Teile (außer genormter Zukaufteile) erfolgt komplett in Deutschland auf modernsten Werkzeugautomaten. Zur reproduzierbaren Crimphöhe, getrennt für Draht- und Isolationscrimp, ist das Werkzeug mit einem Feineinstellkopf ausgestattet. Optionen, wie z.B. Stückzahlzähler, spezielle Klappauswerfer, integrierte Zwangsauswerfer, Pneumatikvorschub, Schliffbilder usw., stehen zur Verfügung.
RE-Y(St)YSWAY-fl-PIMF & RE-Yw(St)YwSWAYw-fl-PIMF

RE-Y(St)YSWAY-fl-PIMF & RE-Yw(St)YwSWAYw-fl-PIMF

INSTRUMENTATION CABLES, EN 50288-7MULTI-PAIR, PVC INSULATED, INDIVIDUAL & COLLECTİVE SCREENED, ARMOURED, PVC SHEATHED These cables are used for transmission of analoge and digital signals in instrument and control systems at chemistry and petrochemistry industry plants, power plants, natural gas and petroluem plants, etc... . Instrumentation cables are not allowed for direct connection to a low impedance sources, e.g. public mains electricity supply. For application of 105oC heat resistant, RE-Yw(St)YwSWAYw-PIMF cables are suitable. With blue sheath it is suitable for intrinsically safe systems. The armour above the inner sheath protects the cable from mechanical shocks. These cables are recommended for direct burial. They are for indoor and outdoor installation, in dry and wet locations; on racks, trays, in conduits. Conductor: Plain copper wire, stranded, IEC 60228 Sınıf 2, TS/DIN EN 60228 Sınıf 2 Insulation (Y): PVC compound, 70 oC grade; EN 50290-2-21 Insulation (Yw): PVC compound, 105 oC grade; EN 50290-2-21 Core identification: Black / White ; with numbered tape under , separator tape of the pair screen, Upon request ; Black / White cores numbered 1-1, 2-2,…, Other core configurations manufactured upon request. Pair: Two conductors twisted to a pair PIMF Construction: Polyester tape above the pair, AL-PES tape, over solid tinned copper drain wire, 0,60 mm, Upon request ; Stranded 0,50 mm2 copper drain wire Lay-up: PIMF laid up in layers of optimum pitch Separator: Polyester tape Screen: AL-PES tape over stranded tinned copper drain, wire 0,50 mm2 Inner sheath (Y): PVC compound, 70 oC grade; EN 50290-2-22 Inner sheath (Yw): PVC compound, 105 oC grade; EN 50290-2-22 Armour: Galvenized round steel wire, EN 10257-1 Outer sheath (Y): PVC compound, 70 oC grade; EN 50290-2-22 Outer sheath (Yw): PVC compound, 105 oC grade; EN 50290-2-22 Sheath colour: RAL 9005, Black or RAL 5015, Blue Standard: TS/DIN EN 50288-7 Insulation thickness: 0,50mm2 : 0,40 mm, 0,75mm2 : 0,40 mm, 1,0mm2 : 0,40 mm, 1,3mm2 : 0,45 mm, 1,5mm2 : 0,45 mm Conductor resistance: 0,50mm2 : 36,7 Ω/km, 0,75mm2 : 25,0 Ω/km, 1,0mm2 : 18,5 Ω/km, 1,3mm2 : 14,2 Ω/km, 1,5mm2 : 12,3 Ω/km Insulation resistance: Min. 100 MΩ.km Mutual Capacitance: 0,50 mm2 : max. 190 pF/m, 0,75 mm2 : max. 190 pF/m, 1,0 mm2 : max. 190 pF/m, 1,3 mm2 : max. 200 pF/m, 1,5 mm2 : max. 200 pF/m L / R (ratio) (max.): 0,50mm2 : 25 µH/Ω, 0,75mm2 : 25 µH/Ω, 1,0mm2 : 25 µH/Ω1,30mm2 : 40 µH/Ω, 1,5mm2 : 40 µH/Ω Rated voltage: 300V Test voltage: Urms core-core : 1500 V, Urms core-screen : 1500 V Temperature range (2Y): operation : - 30 oC ~ + 70 oC, ınstallation : - 5 oC ~ + 50 oC Temperature range (2X): operation : - 30 oC ~ + 105 oC, ınstallation : - 5 oC ~ + 50 oC Min. bending radius: 10 x D Flame retardance test: IEC 60332-1 & EN 60332-1
RE-2Y(St)YSWAY-fl-PIMF & RE-2X(St)YSWAY-fl-PIMF

RE-2Y(St)YSWAY-fl-PIMF & RE-2X(St)YSWAY-fl-PIMF

INSTRUMENTATION CABLES, EN 50288-7RE-2Y(St)YSWAY-fl-PIMF,MULTI-PAIR, PE INSULATED, INDIVIDUAL & COLLECTİVE SCREENED, ARMOURED, PVC SHEATHEDRE-2X(St)YSWAY-fl-PIMF,MULTI-PAIR, XLPE INSULATED, INDIVIDUAL & COLLECTIVE SCREENED, ARMOURED, PVC SHEATHED These cables are used for transmission of analoge and digital signals in instrument and control systems at chemistry and petrochemistry industry plants, power plants, natural gas and petroluem plants, etc... . Instrumentation cables are not allowed for direct connection to a low impedance sources, e.g. public mains electricity supply. With blue sheath it is suitable for intrinsically safe systems. The armour above the inner sheath protects the cable from mechanical shocks. These cables are recommended for direct burial. They are for indoor and outdoor installation, in dry and wet locations; on racks, trays, in conduits. Conductor: Plain copper wire, stranded, IEC 60228 Sınıf 2, TS/DIN EN 60228 Sınıf 2 Insulation (2Y): PE compound, EN 50290-2-23; (RE-2Y….) Insulation (2X): XLPE compound, EN 50290-2-29; (RE-2X….) Core identification: Black / White ; with numbered tape under , separator tape of the pair screen, Upon request ; Black / White cores numbered 1-1, 2-2,…, Other core configurations manufactured upon request. Pair: Two conductors twisted to a pair PIMF Construction: Polyester tape above the pair, AL-PES tape, over solid tinned copper drain wire, 0,60 mm, Upon request ; Stranded 0,50 mm2 copper drain wire Lay-up: PIMF laid up in layers of optimum pitch Separator: Polyester tape Screen: AL-PES tape over stranded tinned copper drain, wire 0,50 mm2 Inner sheath (2Y): PVC compound, EN 50290-2-22 Inner sheath (2X): PVC compound, 90OC grade; EN 50290-2-22 Armour: Galvenized round steel wire, EN 10257-1 Outer sheath (2Y): PVC comp., flame retardant; EN 50290-2-22 Outer sheath (2X): PVC compound, 90 oC grade; EN 50290-2-22 Sheath colour: RAL 9005, Black or RAL 5015, Blue Standard: TS/DIN EN 50288-7 Insulation thickness: 0,50mm2 : 0,40 mm, 0,75mm2 : 0,40 mm, 1,0mm2 : 0,40 mm, 1,3mm2 : 0,45 mm, 1,5mm2 : 0,45 mm Conductor resistance: 0,50mm2 : 36,7 Ω/km, 0,75mm2 : 25,0 Ω/km, 1,0mm2 : 18,5 Ω/km, 1,3mm2 : 14,2 Ω/km, 1,5mm2 : 12,3 Ω/km Insulation resistance: Min. 5000 MΩ.km Mutual Capacitance: max. 120 pF/m L / R (ratio) (max.): 0,50mm2 : 25 µH/Ω, 0,75mm2 : 25 µH/Ω, 1,0mm2 : 25 µH/Ω1,30mm2 : 40 µH/Ω, 1,5mm2 : 40 µH/Ω Rated voltage: 300V Test voltage: Urms core-core : 1500 V, Urms core-screen : 1500 V Temperature range (2Y): operation : - 30 oC ~ + 70 oC, ınstallation : - 5 oC ~ + 50 oC Temperature range (2X): operation : - 30 oC ~ + 90 oC, ınstallation : - 5 oC ~ + 50 oC Min. bending radius: 10 x D Flame retardance test: IEC 60332-1 & EN 60332-1
Automatische Bearbeitung von Netzwerkkabeln inklusive Steckermontage

Automatische Bearbeitung von Netzwerkkabeln inklusive Steckermontage

Automatisierte Herstellung von Netzwerkkabeln inklusive Beschriftung und Vorbereitung zum Montieren des Steckers sowie Wickeln, Binden und automatisches Ablegen. Um Kosten zu sparen, beauftragte ein international tätiges Unternehmen Metzner Maschinenbau damit, den Herstellungsprozess seiner Netzwerkkabel inklusive der Vorbereitung zur Steckermontage zu automatisieren. Die speziell dafür entwickelte Fertigungsanlage kann die Kabel abrollen, beschriften, aufrauen, ablängen, abmanteln, wickeln, binden und automatisch ablegen. Das zu bearbeitende Material wird von einem motorisierten Abwickler der Metzner-Partnerfirma Ramatech abgewickelt und über einen Richtapparat einem Thermotransferdrucker zugeführt. Letzterer bedruckt das Kabel mit zwei QR-Codes und einer Seriennummer. Das gewährleistet dem Kunden, dass jedes Kabel im gesamten Be- und Verarbeitungsprozess identifiziert und den bereits durchlaufenen Stationen zugeordnet werden kann. Diese Rückverfolgbarkeit bietet große Vorteile - beispielsweise bei der Fehlerdiagnose. Danach gelangt das Kabel in eine Aufraustation, die die Materialoberfläche leicht anschleift, sodass später die Steckerumspritzung besser haftet. Eine AM 3550 von Metzner Maschinenbau übernimmt das Ablängen und Abmanteln des Kabels, das dann zur Wickelstation und dann von einem Greifer weiter zum Bindeautomat transportiert wird. Letzterer wickelt das Kabel nach kundenspezifischer Vorgabe zu einem Kabelring, der an zwei gegenüberliegenden Seiten so zusammengebunden wird, dass die beiden Kabelenden eine definierte Länge aus dem Ring herausstehen. Dieses bestimmte Wickelbild ist die Voraussetzung für die weitere automatisierte Bearbeitung des Materials mit einer anderen Maschine. VOLLAUTOMATISCHE BEARBEITUNGSLINIE Die Metzner-Spezialentwicklung eine vollautomatische Anlage, die Netzwerkkabel abrollen, beschriften, aufrauen, ablängen, abmanteln, wickeln, binden und automatisch ablegen kann. Für eine automatisierte Herstellung von Netzwerkkabeln inklusive Beschriftung und Vorbereitung zum Montieren des Steckers sowie Wickeln, Binden und automatisches Ablegen. Einen Einblick in den Bearbeitungsprozess erhalten Sie in unserem Produktvideo.
PV Edelstahl Solarpanel Drahtclips Solarpanel Clips

PV Edelstahl Solarpanel Drahtclips Solarpanel Clips

Solar Kabelclip (Bitte erkundigen Sie sich nach Details zu verschiedenen Modellen) Produkt-Spezifikationen Material: 301 Edelstahl Farbe: Weiß Verpackung: 100 Stück//Beutel 500 Stück//Beutel Umgebungstemperaturbereich: -40℃…+85℃ (IEC) SCC-4S/2 (SCC-OD/2) Geeignet für Kabel-OD: 2*4,0mm² Anwendung für Modul Material: 301 Edelstahl Farbe: Weiß Umgebungstemperaturbereich: -40℃…+85℃ (IEC) Verpackung: 100 Stück//Beutel
PV Solar Drahtclips Solarpanel Clips für Metalldächer

PV Solar Drahtclips Solarpanel Clips für Metalldächer

Solar Kabelclips PV Edelstahlclips Korrosionsbeständigkeit für Solar Kabel - Solar Kabelclip (Bitte anfragen für Details zu verschiedenen Modellen)\nProdukt-Spezifikationen\nMaterial: 301 Edelstahl\nFarbe: Weiß\nVerpackung: 100 Stück/Tasche\n500 Stück/Tasche\nUmgebungstemperaturbereich: -40℃…+85℃ (IEC)\nSCC-4S/4 (SCC-OD/4)\nGeeignet für Kabel OD 4*4.0mm²\nAnwendung für Modul\n\nMaterial: 301 Edelstahl\nFarbe: Weiß\nUmgebungstemperaturbereich: -40℃…+85℃ (IEC)
Solarpanel-Drahtclips PV-Kabelclips Solar-Drahtmanagement - Silberne Edelstahlclips für Solar-Kabelmanagement

Solarpanel-Drahtclips PV-Kabelclips Solar-Drahtmanagement - Silberne Edelstahlclips für Solar-Kabelmanagement

Solar Kabelclip (Bitte erkundigen Sie sich nach Details zu verschiedenen Modellen) Produkt-Spezifikationen Material: 301 Edelstahl Farbe: Weiß Verpackung: 100 Stück//Beutel 500 Stück//Beutel Umgebungstemperaturbereich: -40℃…+85℃ (IEC) SCC-6S/4 Geeignet für Kabel-Ø: 4*6,0mm² Anwendung für Modul Material: 301 Edelstahl Farbe: Weiß Umgebungstemperaturbereich: -40℃…+85℃ (IEC) Verpackung: 100 Stück//Beutel